# LightBurn control-machine observation
- Date: 2026-10-24
- Application: LightBurn Pro 2.1.03
- Hardware state: laser physically disconnected by the operator
- Scope: passive UI and local-preference inspection only
## Confirmed in the running application
The window title identified LightBurn Pro `2.1.03` with the operator-verified
`Gradients DepthMap` project open. The active device was `100 JPT E2 MOPA`, the
connection status read `Disconnected`, the port selector read `(Auto)`, and the
loaded material library was `Mopa-100W-110mm`.
The Cuts / Layers panel labels the MOPA controls as `Frequency (kHz)` and
`Q-Pulse (ns)`. This independently establishes the UI display units needed by
the offline importer contract; it does not establish the serialized-file unit
or authorize conversion without the documented normalization rule.
The visible selected-layer controls showed speed `1800 mm/s`, one pass, power
`17%`, frequency `1000 kHz`, and Q-pulse width `10 ns`. The project layer list
also showed an Image layer at `1800 / 59` and two additional layers at
`12 / 59`. These values are observations of the open project, not recommended
recipes.
## Preference cross-check and preserved files
The live preferences still contain four device records. The named JPT profile
is `JCZFiber` over `LibUSB`, has a 110 x 110 mm work area, enables Q-pulse-width
control, and requires framing before start. The profile stores a raw frequency
range of 1 to 4000 and has home-on-startup disabled.
The active preferences file and LightBurn's newest native `.lbprefs` backup
were copied into PrivateStash with before/source-after/copy SHA-256 equality
checks. Their two sanitized public records are in
[`public-lightburn-control-machine-observation.jsonl`](../../evidence/public-lightburn-control-machine-observation.jsonl).
Exact local paths, raw preferences and machine-specific fields remain private.
## Collection limits
The automation screenshot channel repeatedly returned `window capture timed
out`; accessibility-only inspection remained available. Geometry-dependent
controls therefore could not be safely invoked to capture every Device
Settings tab. No substitute Support Data bundle was generated.
No Start or Frame control was used, no USB endpoint or controller was opened,
and no machine setting was intentionally changed. The operator's 110 mm lens
statement remains operator-confirmed rather than photographically verified.
Exterior hardware labels and the complete Device Settings screenshot set remain
open evidence items.