Record the read-only Windows PnP observation of USBLMCV4 at 9588:9899, distinguish the absent local driver from the installer driver family, and omit the device-specific instance suffix from public history.
3.3 KiB
Live USB enumeration — 2026-10-17
Scope and safety boundary
The JPT fiber laser controller was powered through the machine's normal
procedure and connected by USB to the development computer. Inspection was
limited to Windows' existing Plug and Play database using Get-PnpDevice,
Get-PnpDeviceProperty, CIM, and pnputil /enum-devices.
No application opened the USB device. No endpoint was claimed, no driver was installed or changed, and no bytes or controller commands were sent. There was no framing, galvo motion, marking, or laser output.
The complete Windows instance ID contains a device-specific suffix. That suffix is deliberately omitted from this public record.
Sanitized observation
| Property | Observed value |
|---|---|
| Bus-reported description | USBLMCV4 |
| USB VID | 9588 |
| USB PID | 9899 |
| USB device revision descriptor | 0005 |
| Compatible class | FF — vendor-specific |
| Subclass / protocol | 00 / 00 |
| Windows presence | Present |
| Bound function driver | None |
| Windows problem | Code 28, CM_PROB_FAILED_INSTALL |
| Windows explanation | No compatible driver is installed |
| Reboot required | No |
REV_0005 is the USB device revision descriptor (bcdDevice-derived
hardware ID). It must not be relabeled as board revision or firmware version
without independent evidence.
Interpretation
This is the first live confirmation that the connected physical controller
enumerates with the same 9588:9899 identity found in the private installer
metadata. It also matches the constants used by MeerK40t BalorMK's independent
USB implementation. The three independent observations make BalorMK a strong
compatibility candidate:
- private JCZ driver metadata from the known installer snapshot;
- Windows enumeration of the connected controller;
- BalorMK source code targeting the same VID/PID.
The friendly name USBLMCV4 is additional evidence about the controller
generation, but it does not by itself prove every command, source parameter,
correction setting, or safety behavior is compatible.
Problem code 28 is expected on this development computer because neither the vendor driver nor a libusb function driver is installed. It does not indicate that Windows rejected a known driver or that the controller failed to enumerate. No attempt was made to fix it because installing libusb could affect which software can own the controller.
Consequences
- Change the public machine profile's VID/PID status from inferred installer metadata to live-confirmed.
- Retain
Lmcv2uonly as the stock-driver family observed in the installer, not as the driver currently bound on this computer. - Use
9588:9899as an explicit allow-list identity in future test plans, but never as the only machine/profile safety check. - Keep the next experiment offline. The first controller experiment remains a mock trace, not a live USB connection.