# LightBurn control-machine observation
|
|
|
|
- Date: 2026-10-24
|
|
- Application: LightBurn Pro 2.1.03
|
|
- Hardware state: laser physically disconnected by the operator
|
|
- Scope: passive UI and local-preference inspection only
|
|
|
|
## Confirmed in the running application
|
|
|
|
The window title identified LightBurn Pro `2.1.03` with the operator-verified
|
|
`Gradients DepthMap` project open. The active device was `100 JPT E2 MOPA`, the
|
|
connection status read `Disconnected`, the port selector read `(Auto)`, and the
|
|
loaded material library was `Mopa-100W-110mm`.
|
|
|
|
The Cuts / Layers panel labels the MOPA controls as `Frequency (kHz)` and
|
|
`Q-Pulse (ns)`. This independently establishes the UI display units needed by
|
|
the offline importer contract; it does not establish the serialized-file unit
|
|
or authorize conversion without the documented normalization rule.
|
|
|
|
The visible selected-layer controls showed speed `1800 mm/s`, one pass, power
|
|
`17%`, frequency `1000 kHz`, and Q-pulse width `10 ns`. The project layer list
|
|
also showed an Image layer at `1800 / 59` and two additional layers at
|
|
`12 / 59`. These values are observations of the open project, not recommended
|
|
recipes.
|
|
|
|
## Preference cross-check and preserved files
|
|
|
|
The live preferences still contain four device records. The named JPT profile
|
|
is `JCZFiber` over `LibUSB`, has a 110 x 110 mm work area, enables Q-pulse-width
|
|
control, and requires framing before start. The profile stores a raw frequency
|
|
range of 1 to 4000 and has home-on-startup disabled.
|
|
|
|
The active preferences file and LightBurn's newest native `.lbprefs` backup
|
|
were copied into PrivateStash with before/source-after/copy SHA-256 equality
|
|
checks. Five operator-supplied PNG screenshots preserve every tab in the
|
|
general Settings dialog: Editor Settings, Units and Grids, Display,
|
|
Import / Export, and Camera. Their sanitized public records are in
|
|
[`public-lightburn-control-machine-observation.jsonl`](../../evidence/public-lightburn-control-machine-observation.jsonl).
|
|
Exact local paths, raw preferences and machine-specific fields remain private.
|
|
|
|
The screenshots corroborate version `2.1.03` and show millimeters as the design
|
|
unit. DXF import has unit auto-detection enabled with millimeters selected as
|
|
the fallback, while SVG import uses the 96 DPI Inkscape convention with
|
|
auto-detection enabled. The visible output curve tolerance is `0.050 mm`.
|
|
These are observed application settings, not machine-safe processing values.
|
|
|
|
## JPT Device Settings screenshots
|
|
|
|
Three further operator-supplied screenshots preserve every tab in Device
|
|
Settings for `100 JPT E2 MOPA`: Galvo and Basic Settings, Ports and Laser
|
|
Settings, and Additional Settings. The first confirms a 110 x 110 mm field,
|
|
linked metric control/design units, and enabled `Require Framing Before Start`.
|
|
|
|
The laser-source pane identifies the source as `Fiber`, displays fiber type
|
|
`IPG_YLPM`, enables Q-pulse-width control, and shows a UI frequency range of
|
|
`1.000` to `4000.000 kHz`. The device name says JPT while the fiber-type field
|
|
literally displays `IPG_YLPM`; this is recorded as an observed LightBurn value
|
|
without interpreting it as a manufacturer identity or correcting it.
|
|
|
|
The port assignments, correction coefficients, red-dot scaling, jump timing
|
|
and laser timing are retained only in the private screenshots and preference
|
|
snapshot. They are machine-specific evidence, not public defaults. The third
|
|
tab explicitly labels its speed and acceleration fields as preview/simulation
|
|
timing that does not affect the controller.
|
|
|
|
## Collection limits
|
|
|
|
The five general Settings screenshots and three Device Settings screenshots
|
|
close both application-dialog screenshot items. The automation screenshot
|
|
channel itself repeatedly returned `window capture timed out`; the operator
|
|
supplied the screenshots directly instead. No substitute Support Data bundle
|
|
was generated.
|
|
|
|
No Start or Frame control was used, no USB endpoint or controller was opened,
|
|
and no machine setting was intentionally changed. The operator's 110 mm lens
|
|
statement remains operator-confirmed rather than photographically verified.
|
|
Exterior hardware labels and startup/interlock notes remain open evidence
|
|
items.
|