ThePirateRay/docs/research/live-usb-enumeration-2026-10-17.md
Codex efa22ff098 docs: record live JCZ USB enumeration
Record the read-only Windows PnP observation of USBLMCV4 at 9588:9899, distinguish the absent local driver from the installer driver family, and omit the device-specific instance suffix from public history.
2026-10-17 17:15:23 +02:00

3.3 KiB

Live USB enumeration — 2026-10-17

Scope and safety boundary

The JPT fiber laser controller was powered through the machine's normal procedure and connected by USB to the development computer. Inspection was limited to Windows' existing Plug and Play database using Get-PnpDevice, Get-PnpDeviceProperty, CIM, and pnputil /enum-devices.

No application opened the USB device. No endpoint was claimed, no driver was installed or changed, and no bytes or controller commands were sent. There was no framing, galvo motion, marking, or laser output.

The complete Windows instance ID contains a device-specific suffix. That suffix is deliberately omitted from this public record.

Sanitized observation

Property Observed value
Bus-reported description USBLMCV4
USB VID 9588
USB PID 9899
USB device revision descriptor 0005
Compatible class FF — vendor-specific
Subclass / protocol 00 / 00
Windows presence Present
Bound function driver None
Windows problem Code 28, CM_PROB_FAILED_INSTALL
Windows explanation No compatible driver is installed
Reboot required No

REV_0005 is the USB device revision descriptor (bcdDevice-derived hardware ID). It must not be relabeled as board revision or firmware version without independent evidence.

Interpretation

This is the first live confirmation that the connected physical controller enumerates with the same 9588:9899 identity found in the private installer metadata. It also matches the constants used by MeerK40t BalorMK's independent USB implementation. The three independent observations make BalorMK a strong compatibility candidate:

  1. private JCZ driver metadata from the known installer snapshot;
  2. Windows enumeration of the connected controller;
  3. BalorMK source code targeting the same VID/PID.

The friendly name USBLMCV4 is additional evidence about the controller generation, but it does not by itself prove every command, source parameter, correction setting, or safety behavior is compatible.

Problem code 28 is expected on this development computer because neither the vendor driver nor a libusb function driver is installed. It does not indicate that Windows rejected a known driver or that the controller failed to enumerate. No attempt was made to fix it because installing libusb could affect which software can own the controller.

Consequences

  • Change the public machine profile's VID/PID status from inferred installer metadata to live-confirmed.
  • Retain Lmcv2u only as the stock-driver family observed in the installer, not as the driver currently bound on this computer.
  • Use 9588:9899 as an explicit allow-list identity in future test plans, but never as the only machine/profile safety check.
  • Keep the next experiment offline. The first controller experiment remains a mock trace, not a live USB connection.
  • Before any later live connection, choose and document a reversible Windows driver strategy and preserve the current production computer's driver state.